ISO Series –
Easily installable differential pressure units

An isolation facility aims to isolate infectious patients (negative pressure) or to protect immune-compromised patients (positive pressure). By creating a pressure difference between the room and adjacent areas, airflow goes either towards the room (negative pressure) or towards adjacent areas (positive pressure). This pressure difference and corresponding airflow ensures elimination of (cross-) infections by airborne contamination.

The units house state-of-the-art technology which achieves pressure difference and intended airflow within 30 seconds of deployment, and boasts an impressive installation time of just half a day, without making major infrastructural changes.

With its high-performance ULPA15 filter, the ISO devices guarantee hygiene of the utmost standard. Additionally, other numerous features such as intuitive controls and automatic alarm functions by means of wall-mounted remote control are included to allow easy control.

The ISO is perfectly suited for settings where pressure difference between a room and adjacent areas is required.

ISO 120
ISO 120
ISO 200
ISO 200
ISO 520
ISO 520

ISO 120

Isolation Unit, 1-piece, for positive or negative room pressure

This Isolation Unit is made for installation in suspended or false ceilings, and walls.
Can be connected to an existing ventilation system or new tube system. Reccommended for isolation rooms up to 12m2 / 30m3.

Depending on the installation, positive (for immune-compromised) or negative (for infectious patients) pressure is generated inside the room (easily up to 20 Pascal).
Filters used in this Isolation Unit are of HEPA14 or ULPA15 quality, leaktested and airtight secured.

ISO120 can be used with Remote Control RC100 or RC200.

ISO 210

Isolation Unit, 2-piece, for positive or negative room pressure

This Isolation Unit is made for installation on walls or windows. Pressure differences up to 20 Pascal are easily generated. Reccommended for isolation rooms up to 12m2 / 30m3. ISO210 can be used with Remote Control RC100 or RC200.

Negative pressure is obtained when the filter unit is placed inside the room, and the ventilator unit is placed outside the room. (infectious patients) Positive pressure is obtained when the ventilator unit is placed inside the room and the filter unit is placed outside the room. (immune-compromised patients).

Both parts are connected by a tube – through the wall – which contains an air back-pressure flap (standard) and fire damper (optional). Filters used in this Isolation Unit are of HEPA14 or ULPA15 quality, leaktested and airtight secured.

ISO 520

Isolation Unit, 1-piece, for positive or negative room pressure

This Isolation Unit is made for installation in suspended or false ceilings, and walls. Can be connected to an existing ventilation system or new tube system. Reccommended for isolation rooms up to 40m2 / 120m3.

Depending on the installation, positive (for immune-compromised) or negative (for infectious patients) pressure is generated inside the room (easily up to 20 Pascal). Filters used in this Isolation Unit are of HEPA14 or ULPA15 quality, leaktested and airtight secured.

ISO520 can be used with Remote Control RC100 or RC200.

Compare our models

Installation

  • 1 day installation time max.
  • Can be installed on a false ceiling or directly to wall or ceiling
  • For isolation rooms up to 12m²
  • Dimensions: 35 x 35 x 25 cm

Performance

  • Pressure results within 30 seconds
  • Contributes to ISO6/ ISO7 cleanroom classifi cation
  • Clean air capacity: 135 m³/h
  • Noise level: between 20 ≤ 55 dB

Filtration & hardware

  • ULPA15 main filter
  • ISO ePM10 50% pre-filter (old norm M5, EN779)
  • Certifi ed leak-tested filters (EN1822)
  • Integrated pressure difference system
  • Standard RC100 remote control
  • RC200 remote control with additional pressure difference monitor OPTIONAL
  • Hygiene and performance control on filter status by sensor and timer

Installation

  • 1 day installation time max.
  • Wall-mounted
  • For isolation rooms of up to 12m³
  • Dimensions: 32 x 43 x 14 cm + 32 x 43 x 14 cm

Performance

  • Pressure results within 30 seconds
  • Contributes to ISO6/ISO7 cleanroom classifi cation
  • Clean air capacity: 135m3/h
  • Noise level: between 20 ≤ 55 dB

Filtration & hardware

  • ULPA15 main fi lter
  • ISO ePM10 50% pre-filter (old norm M5, EN779)
  • Certifi ed leak-tested filters (EN1822)
  • Integrated pressure difference system
  • Standard RC100 remote control
  • RC200 remote control with additional pressure difference monitor OPTIONAL
  • Hygiene and performance control on filter status by sensor and timer

Installation

  • 1 day installation time max.
  • Installed between floor/wall
  • For isolation rooms of up to 30m²
  • Dimensions: 54 x 54 x 27 cm

Performance

  • Pressure results within 30 seconds
  • Contributes to ISO6/ISO7 cleanroom classifi cation
  • Clean air capacity: 1000m3/h
  • Noise level: between 20 ≤ 55 dB

Filtration & hardware

  • ULPA15 main filter
  • ISO ePM10 50% pre-filter (old norm M5, EN779)
  • Certifi ed leak-tested filters (EN1822)
  • Integrated pressure difference system
  • Standard RC100 remote control
  • RC200 remote control with additional pressure difference monitor OPTIONAL
  • Hygiene and performance control on fi lter status by sensor and timer

MedicCleanAir benefits

Automatic differential pressure regulation

Automatic pressure loss alert

Filter detection by ID code (filter condition)

Complies with CDC guidelines (Centres for Disease Control and Prevention)

Used in hospitals, clinics and medical facilities

General use in
Operating theatres, intensive care units, isolation wards, etc.



Immune-compromised patients
Oncology, haematology, neonatology, transplant, burn units, etc.

Infectious patients
Tuberculosis, chicken pox, SARS, MRSA, flu viruses, etc.