Pro Series –
Mobile Air purification Units
Our PRO devices are mobile medically & clinically tested air purifiers that can be quickly deployed to achieve immediate impact on the air quality levels of all types of medical and high care environments. They are clinically proven to reduce the number of infected patients up to zero.
These PRO devices are best suited for use in medical environments such as, but not limited to patient rooms, intensive care units, operating theaters, isolation rooms, laboratories, dental clinics and plastic surgery centers. They can safeguard immune-compromised and infectious patients as well as protect hospital staff and visitors from infection.
Upon deployment, the MedicCleanAir Pro series can guarantee protection against harmful viruses, bacteria, and fungi within twenty minutes of operation, having an installation time of no more than an hour.
PRO 130
Air purification unit for cleaning room air
The Pro air purification unit cleans the air inside the room. The Pro unit is used for the protection of vulnerable (immune-compromised) patients, protection against infectious patients, the elimination of aspergillus during renovation works, and for the upgrading of air quality in operating theatres, ICUs, isolation rooms.
The Pro unit gives immediate results (within 20 minutes max) and once deployed maintains integrity of the air quality at all times.
PRO 300
Air purification unit for cleaning room air
The Pro air purification unit cleans the air inside the room. The Pro unit is used for the protection of vulnerable (immune-compromised) patients, protection against infectious patients, the elimination of aspergillus during renovation works, and for the upgrading of air quality in operating theatres, ICUs, isolation rooms.
The Pro unit gives immediate results (within 20 minutes max) and once deployed maintains integrity of the air quality at all times.
PRO 600
Air purification unit for cleaning room air
Text für Pro 600
The Pro air purification unit cleans the air inside the room. The Pro unit is used for the protection of vulnerable (immune-compromised) patients, protection against infectious patients, the elimination of aspergillus during renovation works, and for the upgrading of air quality in operating theatres, ICUs, isolation rooms.
Pre-filtration filters on the outside of the unit
Indoor work leads to an increased concentration of aspergillus. In order to protect the high effiency particulate air filter inside the unit during building activities, pre-filtration frames with filters are added to the outside of the device.
The life-time of the high efficiency particulate air filter inside the unit is therefore largely extended. The prefilters are supplied in packages and are easily changed.
Pre-filtration filters on the outside of the unit
Indoor work leads to an increased concentration of aspergillus. In order to protect the high effiency particulate air filter inside the unit during building activities, pre-filtration frames with filters are added to the outside of the device.
The life-time of the high efficiency particulate air filter inside the unit is therefore largely extended. The prefilters are supplied in packages and are easily changed.
Compare our models
Installation
- 1 hour installation time max.
- Recommended room size: 25m²
- Delivered with wall brackets
- Dimensions: 56 x 37 x 34 cm
Performance
- Results within 20 minutes
- Contributes to ISO6/ISO7 cleanroom classification
- Clean air capacity: 75 to 450 m³/h
- Noise level: between 20 ≤ 55 dB
Filtration & hardware
- HEPA14 main filter. ULPA15 filter is optional.
- Activated carbon filter
- ISO ePM1 50% pre-filter (old norm F7, EN779).
- ISO ePM10 50% pre-filter (old norm M5, EN779) on the outside of the device OPTIONAL
- Certified leak-tested filters (EN1822)
- RC100 remote controller OPTIONAL
- Hygiene and performance control on filter status
Installation
- 1 hour installation time max.
- Recommended room size: 40m2
- Delivered with wall brackets
- Dimensions: 69,5 x 54,9 x 46,5 cm
Performance
- Results within 20 minutes
- Contributes to ISO6/ISO7 cleanroom classification
- Clean air capacity: 170 to 900 m³/h
- Noise level: between 20 ≤ 55 dB
Filtration & hardware
- HEPA14 main filter. ULPA15 filter is optional.
- Activated carbon filter
- ISO ePM1 50% pre-filter (old norm F7, EN779)
- ISO ePM10 50% pre-filter (old norm M5, EN779) on the outside of the device OPTIONAL
- Certified leak-tested filters (EN1822)
- RC100 remote controller OPTIONAL
- Hygiene and performance control on filter status by a sensor and timer
Installation
- Text für Pro 600
Performance
- Text für Pro 600
Filtration & hardware
- Text für Pro 600
MedicCleanAir benefits
360° uniform air extraction and air supply
Is able to achieve ISO8, ISO7 or even ISO6 level
Filter detection by ID code (filter condition)
Remote Control by key switch (security)
Used in hospitals, clinics and medical facilities
General use in
Operating theatres, intensive care units, isolation wards, etc.
Immune-compromised patients
Oncology, haematology, neonatology, transplant, burn units, etc.
Infectious patients
Tuberculosis, chicken pox, SARS, MRSA, flu viruses, etc.
Downloads MedicCleanAir